Wet Back Design Eliminates Refractory Rear Door & Baffles Between Flue Gas Passes

  • Natural Gas
  • Oil
  • Combination
  • Steam
  • Hot Water

euro-series_shrink.png#asset:245

Standard Features

  • Boiler is of the three-pass, scotch type, built and stamped in accordance with the requirements of the ASME Code, and listed by the National Board of Boilers and Pressure Vessel Inspectors.
  • Large combustion chamber with low heat release for complete combustion. Smoke box is rear-mounted with slip-on stack connector.
  • Access to fireside is accomplished with hinged and davited front and rear doors. Flame observation ports are located on front and rear.
  • Openings for vessel cleanout and inspection of waterside are provided with 3" x 4" hand holes, and 12" x 16" manway access.
  • Insulated with 2" high density mineral wool, lagged with 22 gage grip jacketing, baked on finish to resist chipping and fading.
  • Firetubes are rolled and beaded on power boilers, expanded and flared on low pressure boilers
  • Supports include lifting lugs securely welded to the top of shell; structural steel support legs on skids support the boiler so that special foundations are not required.

Standard Steam Trim

  • Operating & high limit pressure control
  • Modulating pressure control (when appl.)
  • Water column with gauge glass, combination low water cut-off & pump control
  • Probe Aux, L.W.C.O.Steam pressure gauge, syphon & test cock
  • Water column drain valve
  • Safety relief valve(s) per ASME Code

Standard Water Trim

  • Operating & high limit temperature control
  • Modulating temperature control (when appl.)
  • Probe type low water cut-off control
  • Combination pressure & temperature gauge
  • Hot water return baffle for shock resistance
  • Safety relief valve(s) per ASME Code

Boiler Design

Three-Pass "Scotch Marine" Firetube design with stress relieving "Wetback" construction. Pressure designs for steam are 15-300 psi. 100-600 hp. 250 psi. max. for 700-1500 hp. and 200 psi. max. for 1800-2000 hp. Hot Water pressures models are from 30-160 psi. High pressure, high temperature Section I hot water boilers available. Factory assembled with trim, tested, ASME code, UL, and CSD-1 standards.

Steam Model Trim

Safety relief valve, operating pressure control, high limit pressure control with manual reset, steam pressure gauge with syphon, combination pump control and low water cut-off with gauge glass assembly and drain valve, auxiliary low water cut-off with manual reset.

Hot Water Model Trim

Safety relief valve, operating temperature control, high limit temperature control with manual reset, combination pressure & temperature gauge, low water cut-off control with manual reset. BURNER: Matched UL listed "forced draft" power burners with factory prepiped, wired and tested fuel configurations for natural gas, propane (LP) gas, No. 2 (diesel) oil, or combination of both gas/oil.


About Hurst Boiler & Welding Company

Hurst Boiler offers a complete product line of natural gas, oil, digester gas and off gas fired steam and hot water boilers, as well as a broad array of ancillary equipment including blowdown separators, surge tanks and pressurized feedwater tanks.

  • Scotch Marine (firetube)
  • Firebox
  • Vertical tubed & tubeless boilers
  • Feedwater systems
  • Blowdown separators
  • Deaerator systems
  • Solid fuel-fired boilers
  • Hybrid HD series